blob: 0ade98dba7a680333096cfc14486852173f06978 [file] [log] [blame]
/**
* @license
* Copyright 2020 The Emscripten Authors
* SPDX-License-Identifier: MIT
*/
#if ASSERTIONS
function legacyModuleProp(prop, newName, incomming=true) {
if (!Object.getOwnPropertyDescriptor(Module, prop)) {
Object.defineProperty(Module, prop, {
configurable: true,
get() {
let extra = incomming ? ' (the initial value can be provided on Module, but after startup the value is only looked for on a local variable of that name)' : '';
abort(`\`Module.${prop}\` has been replaced by \`${newName}\`` + extra);
}
});
}
}
function ignoredModuleProp(prop) {
if (Object.getOwnPropertyDescriptor(Module, prop)) {
abort(`\`Module.${prop}\` was supplied but \`${prop}\` not included in INCOMING_MODULE_JS_API`);
}
}
// forcing the filesystem exports a few things by default
function isExportedByForceFilesystem(name) {
return name === 'FS_createPath' ||
name === 'FS_createDataFile' ||
name === 'FS_createPreloadedFile' ||
name === 'FS_unlink' ||
name === 'addRunDependency' ||
#if !WASMFS
// The old FS has some functionality that WasmFS lacks.
name === 'FS_createLazyFile' ||
name === 'FS_createDevice' ||
#endif
name === 'removeRunDependency';
}
function missingGlobal(sym, msg) {
if (typeof globalThis !== 'undefined') {
Object.defineProperty(globalThis, sym, {
configurable: true,
get() {
warnOnce(`\`${sym}\` is not longer defined by emscripten. ${msg}`);
return undefined;
}
});
}
}
missingGlobal('buffer', 'Please use HEAP8.buffer or wasmMemory.buffer');
missingGlobal('asm', 'Please use wasmExports instead');
function missingLibrarySymbol(sym) {
if (typeof globalThis !== 'undefined' && !Object.getOwnPropertyDescriptor(globalThis, sym)) {
Object.defineProperty(globalThis, sym, {
configurable: true,
get() {
// Can't `abort()` here because it would break code that does runtime
// checks. e.g. `if (typeof SDL === 'undefined')`.
var msg = `\`${sym}\` is a library symbol and not included by default; add it to your library.js __deps or to DEFAULT_LIBRARY_FUNCS_TO_INCLUDE on the command line`;
// DEFAULT_LIBRARY_FUNCS_TO_INCLUDE requires the name as it appears in
// library.js, which means $name for a JS name with no prefix, or name
// for a JS name like _name.
var librarySymbol = sym;
if (!librarySymbol.startsWith('_')) {
librarySymbol = '$' + sym;
}
msg += ` (e.g. -sDEFAULT_LIBRARY_FUNCS_TO_INCLUDE='${librarySymbol}')`;
if (isExportedByForceFilesystem(sym)) {
msg += '. Alternatively, forcing filesystem support (-sFORCE_FILESYSTEM) can export this for you';
}
warnOnce(msg);
return undefined;
}
});
}
// Any symbol that is not included from the JS libary is also (by definition)
// not exported on the Module object.
unexportedRuntimeSymbol(sym);
}
function unexportedRuntimeSymbol(sym) {
if (!Object.getOwnPropertyDescriptor(Module, sym)) {
Object.defineProperty(Module, sym, {
configurable: true,
get() {
var msg = `'${sym}' was not exported. add it to EXPORTED_RUNTIME_METHODS (see the Emscripten FAQ)`;
if (isExportedByForceFilesystem(sym)) {
msg += '. Alternatively, forcing filesystem support (-sFORCE_FILESYSTEM) can export this for you';
}
abort(msg);
}
});
}
}
#if ASSERTIONS == 2
var MAX_UINT8 = (2 ** 8) - 1;
var MAX_UINT16 = (2 ** 16) - 1;
var MAX_UINT32 = (2 ** 32) - 1;
var MAX_UINT53 = (2 ** 53) - 1;
var MAX_UINT64 = (2 ** 64) - 1;
var MIN_INT8 = - (2 ** ( 8 - 1)) + 1;
var MIN_INT16 = - (2 ** (16 - 1)) + 1;
var MIN_INT32 = - (2 ** (32 - 1)) + 1;
var MIN_INT53 = - (2 ** (53 - 1)) + 1;
var MIN_INT64 = - (2 ** (64 - 1)) + 1;
function checkInt(value, bits, min, max) {
assert(Number.isInteger(Number(value)), `attempt to write non-integer (${value}) into integer heap`);
assert(value <= max, `value (${value}) too large to write as ${bits}-bit value`);
assert(value >= min, `value (${value}) too small to write as ${bits}-bit value`);
}
var checkInt1 = (value) => checkInt(value, 1, 1);
var checkInt8 = (value) => checkInt(value, 8, MIN_INT8, MAX_UINT8);
var checkInt16 = (value) => checkInt(value, 16, MIN_INT16, MAX_UINT16);
var checkInt32 = (value) => checkInt(value, 32, MIN_INT32, MAX_UINT32);
var checkInt53 = (value) => checkInt(value, 53, MIN_INT53, MAX_UINT53);
var checkInt64 = (value) => checkInt(value, 64, MIN_INT64, MAX_UINT64);
#endif // ASSERTIONS == 2
#endif // ASSERTIONS
#if RUNTIME_DEBUG
var runtimeDebug = true; // Switch to false at runtime to disable logging at the right times
var printObjectList = [];
function prettyPrint(arg) {
if (typeof arg == 'undefined') return '!UNDEFINED!';
if (typeof arg == 'boolean') arg = arg + 0;
if (!arg) return arg;
var index = printObjectList.indexOf(arg);
if (index >= 0) return '<' + arg + '|' + index + '>';
if (arg.toString() == '[object HTMLImageElement]') {
return arg + '\n\n';
}
if (arg.byteLength) {
return '{' + Array.prototype.slice.call(arg, 0, Math.min(arg.length, 400)) + '}';
}
if (typeof arg == 'function') {
return '<function>';
} else if (typeof arg == 'object') {
printObjectList.push(arg);
return '<' + arg + '|' + (printObjectList.length-1) + '>';
} else if (typeof arg == 'number') {
if (arg > 0) return ptrToString(arg) + ' (' + arg + ')';
}
return arg;
}
#endif
#if ASSERTIONS || RUNTIME_DEBUG || AUTODEBUG
// Used by XXXXX_DEBUG settings to output debug messages.
function dbg(text) {
#if ENVIRONMENT_MAY_BE_NODE && PTHREADS
// Avoid using the console for debugging in multi-threaded node applications
// See https://github.com/emscripten-core/emscripten/issues/14804
if (ENVIRONMENT_IS_NODE) {
fs.writeSync(2, Array.from(arguments).join(' ') + '\n');
} else
#endif
// TODO(sbc): Make this configurable somehow. Its not always convenient for
// logging to show up as warnings.
console.warn.apply(console, arguments);
}
#endif