Tegra2: Correct the power-on sequence of AUO panel for Aebl

The LCD power-on sequence has to match AUO panel timing specification to avoid display noise on Aebl

BUG=chrome-os-partner:2699

TEST=test on Aebl, No garbage during power-on

Change-Id: I4f59d1768da3ebbb40661ac0d369582e8101ebc1
Signed-off-by: Dilan Lee <[email protected]>
Reviewed-on: http://gerrit.chromium.org/gerrit/749
Reviewed-by: Tom Warren <[email protected]>
Reviewed-by: Simon Glass <[email protected]>
1 file changed